| Customization: | Available |
|---|---|
| Type: | Cabinet Air Conditioner |
| Air Tube Material: | Galvanized Sheet |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency








Get a Free Project Proposal
Not sure whether VRF air conditioner (high & space indoor unit) is suitable for your project?
Send us your project information, and we will help recommend the suitable model and quantity.
1. Workshop length, width and height
2. Project location/country
3. Summer outdoor temperature
4. Required indoor temperature
5. Roof and wall insulation condition
6. Whether the space is partitioned
7. Heat source inside the workshop
8. Project drawing, layout or CAD file
9. Site photos or videos if available
Q1: Is this solution suitable for buildings over 4 meters?
A: Yes. This solution is specially designed for high and large spaces such as factories, workshops and warehouses above 4 meters.
Q2: Does the system need large air ducts?
A: No. One of the main advantages of this solution is that it does not require large ductwork, which helps simplify installation.
Q3: What is the difference from normal VRF indoor units?
A: Normal VRF indoor units are mainly used in offices or standard commercial areas.
Our high space indoor units are designed specially for larges spaces.
Q4: Can the air really reach the working zone?
A: The unit is designed to deliver conditioned air more effectively to the occupied zone, which is very important in high ceiling buildings.
Q5: Is it suitable for existing workshops?
A: Yes. It can be a good option for retrofit projects where installing large air ducts is difficult.
Q6: Is it better than evaporative air coolers?
A: For buyers who need more precise temperature control and do not want extra humidity, this solution is often a better choice.
Q7: Can different areas be controlled separately?
A: Yes. VRF systems offer flexible zoning, which can help manage different areas more conveniently.
Q8: What information do you need for model selection?
A: We need building size, height, project location, target indoor temperature, insulation condition and project drawings if available.
Q9: Can you help with project proposal and model recommendation?
A: Yes. Send us your project details, and we can help recommend the suitable solution.
Q10: Is this solution suitable for factory cooling only?
A: No. It can also be used in warehouses, logistics centers, exhibition halls and other high-space buildings.
Q11: Who we are?
A: AirTS was established in 2005 as a technology-driven enterprise that integrates research and development, manufacturing, sales, and technical services for energy-saving equipment. We are specialized in providing comprehensive solutions for system design,implementation, operation, and maintenance of energy-saving projects.
Q12: How to guarantee quality?
A: Always a pre-production sample before mass production; always final Inspection before shipment;
Q13: What buy from us?
A: Heating units, heating and cooling units, gas heating units, gas radiation units, VRF air conditioners, hot air curtain units, industrial HVLS fans, industrial control systems, and other products tailored for large spaces.
Q14: Why buy from us not from other suppliers?
A: With 21 years' experience in the market, AirTS has became No.1 market share in China.
Q15: What services we can provide?
A: Delivery Terms: FOB, CFR, EXW, CIF, Express Delivery;
Payment Currency: USD, CNY;
Payment Type: T/T, L/C, PayPal;
Language: English, Chinese
Looking for a Better Cooling Solution for a High Ceiling Large Space?
If your factory, workshop, or warehouse has a ceiling height over 4 meters and traditional HVAC systems fail to deliver ideal results, our ductless solution is the ultimate choice.
Submit your project requirements today, and our engineers will customize the perfect model and tailored solution for you.
Get Free Design Plan
Working Principle
The VRF air conditioners, also known as "one-to-many," is a type of system where one outdoor unit is connected to several indoor units. Each indoor unit can operate independently or be controlled together. The system has an outdoor unit connected by pipes to indoor units that have components like outdoor heat exchangers, compressors, and other parts. The indoor units consist of fans and direct cooling elements. Using the pipes, the outdoor unit can supply cooling liquid to many indoor units. It controls the compressor's cooling fluid circulation and the flow into various indoor heat exchangers to meet the indoor cooling and heating needs.
The system's working principle is simple: the indoor temperature sensor controls the valve on the indoor unit's cooling pipe. By adjusting the pressure, the system can control the outdoor unit's compressor speed or change its operating mode to adjust the cooling capacity according to the load.
The multi-unit system has some key features
1. Significant energy savings: The system adjusts the compressor speed and refrigerant flow automatically to operate more efficiently, reducing energy consumption during lighter use and lowering overall costs.
2. Space-saving design: The outdoor units, usually installed on the roof, take up no extra space. With just slim refrigerant piping and condensate drain pipe, the system's layout can save on building height and costs compared to bulky traditional water systems.
3. Easy installation and reliable operation: Compared to centralized water systems, the multi-unit system has a simple setup, making it ideal for large industrial and commercial spaces.With fewer components, the system runs reliably and safely.
4. Meeting different room requirements: The system can be arranged to meet various room needs. In some setups, while some units cool, others can heat simultaneously. In winter, the system can cool one area and heat another, reducing energy consumption and meeting diverse air conditioning needs.
|
Model
|
AirTS-335N
|
|
| Rotating speed of fan | r/min | 0~1300 |
| Standard circulating airflow | m³/h | 0~5500 |
| Rated cooling capacity | kW | 33.5 |
| Rated heating capacity | kW | 37.5 |
| Voltage | V | 380±5% |
| Electric power | kW | 0~0.79 |
| Current | A | 0~1.45 |
| Suitable installation height | m | 3~6 |
| Control mode | VAV stepless regulation | |
| Noise | dB | <50 |
|
Outdoor Module Frequency |
AirTS- 335AX |
AirTS- 400AX |
AirTS- 450AX |
AirTS- 500AX |
AirTS- 560AX |
AirTS- 615AX |
AirTS- 670AX |
AirTS- 730AX |
AirTS- 785AX |
AirTS- 850AX |
AirTS- 900AX |
||
| Power | HP | 12 | 14 | 16 | 18 | 20 | 22 | 24 | 26 | 28 | 30 | 32 | |
| Power supply | Three-phase and five-wire system 380V3N 5%~50HZ | ||||||||||||
| *1 Rated refrigerating capacity | kW | 33.5 | 40 | 45 | 50.4 | 56 | 61.5 | 68.5 | 73.5 | 78.5 | 85 | 90 | |
| *2 Rated heating capacity | kW | 37.5 | 45 | 50 | 56 | 63 | 69 | 75 | 81.5 | 87.5 | 95 | 100 | |
| Rated power consumption | Cooling | kW | 8.4 | 10.25 | 12.1 | 13.5 | 16 | 17.87 | 18.6 | 19.27 | 20.95 | 22.85 | 24.65 |
| Heating | kW | 8.3 | 10.28 | 12.15 | 13.6 | 15.6 | 17.3 | 17.6 | 19.01 | 20.55 | 23.05 | 24.15 | |
| Machine size | L×W×H | mm | 930×860×1690 | 1240×860×1690 | 1500×860×1690 | 1900×860×1690 | |||||||
| APF | 4.9 | 4.9 | 4.8 | 4.7 | 4.75 | 4.7 | 4.5 | 4.6 | 4.6 | 4.55 | 4.5 | ||
| Standard circulating airflow | m3/h | 12000 | 13980 | 25800 | 27000 | ||||||||
| *3 Operating sound | dB | 57 | 59 | 60 | 61 | 62 | 62 | 62 | 62 | 63 | 64 | 64 | |
| On-site piping size | Liquid pipe | mm | φ12.70 | φ12.70 | φ15.88 | φ19.05 | |||||||
| Air pipe | mm | φ25.40 | φ28.58 | φ28.58 | φ31.75 | ||||||||
| Weight | kg | 230 | 285 | 290 | 298 | 345 | 370 | 375 | 450 | 455 | 460 | 465 | |
| Refrigerant | Name | R410A | |||||||||||
| Self-contained filling capacity | kg | 8 | 10 | 10 | 10 | 14 | 14 | 14 | 16 | 20 | 20 | 21 | |
| Running range | Cooling | °C DB | -5~56°C | -5~56°C | |||||||||
| Heating | °C WB | -5~26°C | -5~26°C | ||||||||||
| *4 Maximum fuse wire current | MFA | A | 32 | 40 | 40 | 50 | 63 | 63 | 63 | 80 | 80 | 80 | 80 |
| *4 Minimum line current | MCA | A | 28.4 | 35.2 | 40.2 | 48.1 | 51 | 54 | 55 | 66 | 68 | 70.1 | 72 |
| Note: Modules can be assembled, the maximum assembled total refrigerating capacity is 64HP. | |||||||||||||||
|
1. Nominal cooling capacity is determined according to the following conditions: Indoor temperature: 27.0 ºC DB/19.0 ºC WB, outdoor temperature: 35.0 ºC DB, equivalent pipe length: 10m, difference of height: 0m; |
AirTS was established in 2005 as a technology-driven enterprise that integrates research and development, manufacturing, sales, and technical services for energy-saving equipment. We are specialized in providing comprehensive solutions for system design, implementation, operation, and maintenance of energy-saving projects.
AirTS product line primarily consists of energy-efficient air conditioning systems specifically designed for high and large space, encompassing heating units, heating and cooling units, gas heating units, gas radiation units, VRF air conditioners, hot air curtain units, industrial HVLS fans, industrial control systems, and other products tailored for large spaces. These solutions effectively resolve diverse requirements such as heating, cooling, ventilation, humidification, dehumidification, dust removal, and automation control in buildings ranging from 4 to 30 meters in height.

To better ensure the safety of your goods, professional, environmentally friendly, convenient and efficient packaging services will be provided.