Air Conditioning Unit HVAC System Airts Fresh Air Natural Gas Direct Fired Air Heater Installed on Roof for Large Space 6-30 Meter Workshop Warehouse

Product Details
Customization: Available
After-sales Service: Long Term
Warranty: 1 Year
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (8)
  • Air Conditioning Unit HVAC System Airts Fresh Air Natural Gas Direct Fired Air Heater Installed on Roof for Large Space 6-30 Meter Workshop Warehouse
  • Air Conditioning Unit HVAC System Airts Fresh Air Natural Gas Direct Fired Air Heater Installed on Roof for Large Space 6-30 Meter Workshop Warehouse
  • Air Conditioning Unit HVAC System Airts Fresh Air Natural Gas Direct Fired Air Heater Installed on Roof for Large Space 6-30 Meter Workshop Warehouse
  • Air Conditioning Unit HVAC System Airts Fresh Air Natural Gas Direct Fired Air Heater Installed on Roof for Large Space 6-30 Meter Workshop Warehouse
  • Air Conditioning Unit HVAC System Airts Fresh Air Natural Gas Direct Fired Air Heater Installed on Roof for Large Space 6-30 Meter Workshop Warehouse
  • Air Conditioning Unit HVAC System Airts Fresh Air Natural Gas Direct Fired Air Heater Installed on Roof for Large Space 6-30 Meter Workshop Warehouse
Find Similar Products

Basic Info.

Model NO.
AirTS-GFT
Application
Heater, Workshop,Farms,Warehouse
Principle
Recuperative Heat Exchanger
Style
Storage-Type
Material
Stainless Steel
Air Consumption
5.21 M3/H
Supply Gas Pressure
5~10 Kpa
Heating Capacity
0~57kw
Control System
Wireless Control System
Control Mode
Stepless Regulation of Gas Volume and Wind Speed
Function
Heating,Fresh Air,Top Heat Recovery
Installed Height
4-17 Meter
Standard Circulating Air Volume
0~10200 M3/H
Transport Package
Wooden Pallet
Specification
metal
Trademark
AirTS
Origin
China
HS Code
8415830000
Production Capacity
50000 Unts/ Year

Packaging & Delivery

Package Size
120.00cm * 200.00cm * 220.00cm
Package Gross Weight
250.000kg

Product Description

Air Conditioning Unit HVAC System Airts Fresh Air Natural Gas Direct Fired Air Heater Installed on Roof for Large Space 6-30 Meter Workshop Warehouse

Working Principle

Natural gas mixed with air burned through burner, and the heat passes through heat exchanger.
The axial fan provides power to top side, make the return air take away the heat through heat exchager.
After two pressure boosts and silencers, hot air sent to the heating area in the floor.

Air Conditioning Unit HVAC System Airts Fresh Air Natural Gas Direct Fired Air Heater Installed on Roof for Large Space 6-30 Meter Workshop Warehouse

Air Conditioning Unit HVAC System Airts Fresh Air Natural Gas Direct Fired Air Heater Installed on Roof for Large Space 6-30 Meter Workshop WarehouseAir Conditioning Unit HVAC System Airts Fresh Air Natural Gas Direct Fired Air Heater Installed on Roof for Large Space 6-30 Meter Workshop Warehouse
Technical Comparison

System configuration of gas heating unit

Function: heatingAir Conditioning Unit HVAC System Airts Fresh Air Natural Gas Direct Fired Air Heater Installed on Roof for Large Space 6-30 Meter Workshop Warehouse1. Energy source: natural gas, electricity
2. Civil engineering requirements: none
3. Personnel requirements: unattended system
4. System configuration: gas heating unit
 

System configuration of traditional heating unit

Air Conditioning Unit HVAC System Airts Fresh Air Natural Gas Direct Fired Air Heater Installed on Roof for Large Space 6-30 Meter Workshop Warehouse

1. Energy source: water, electricity, natural gas
2. Civil engineering requirements: boiler room or heat exchange station
3. Personnel requirements: furnace worker, maintenance worker
4. System configuration: gas boiler or thermal power plant, circulating water pump, primary and secondary circulating water network, heat exchanger, boiler room or heat exchange station, water tank, etc.
 

The gas heating system as follows

Our heating units forcedly and quickly send the hot air down, make the temp in the working area rise rapidly.

Air Conditioning Unit HVAC System Airts Fresh Air Natural Gas Direct Fired Air Heater Installed on Roof for Large Space 6-30 Meter Workshop Warehouse

A. Low initial investment - 20% lower initial investment compared to traditional methods
B. Low running costs - direct heating, waterless system saves 40% of operating costs
C. Low maintenance costs - simple system and low failure rate 

The water heating system as follows

Air Conditioning Unit HVAC System Airts Fresh Air Natural Gas Direct Fired Air Heater Installed on Roof for Large Space 6-30 Meter Workshop Warehouse

A. High initial investment - complex system and many equipment

B. High running costs - 30~40% of non-heating ineffective losses

C. High maintenance costs - more equipment, more failure points, high failure rate
 

Advantage of gas heating unit

1. Thermal conversion efficiency is above 96%.
2. Deliver heat directly and possess the capability to recover heat from the top of the space, thereby reducing temperature gradients within the space.
3. Stepless regulation of heating capacity (automatically adjust gas flow according to temperature requirement) and accurate temperature control.
4. To meet the heating requirements of the same project, the quantity of equipment is half compared with gas radiation unit.
5. The air volume is accurately proportioned according to the gas flow (one-thousandth fine adjustment) to ensure full combustion and environmentally friendly emissions.

Air Conditioning Unit HVAC System Airts Fresh Air Natural Gas Direct Fired Air Heater Installed on Roof for Large Space 6-30 Meter Workshop Warehouse

 

Fresh Air/Roof Heat Recovery Gas Heating Unit
Model   AirTS-GFT
Rotating speed of fan r/min 0~860
Standard circulating air volume m³/h 0~10000
Voltage V 380±5%
Electric power kW 0~1.91
Current A 0~4.2
Suitable installation height m 4~17
Heating capacity kW 0~56.18
Air consumption m³/h 5.21 (Working condition)/ 5.64 (Standard condition)
Supply gas pressure Kpa 5~10
Working pressure Kpa 2
Thermal efficiency η 99.90%
Control mode   Stepless regulation of variable gas volume and wind speed
Noise dB <60

 

Air Conditioning Unit HVAC System Airts Fresh Air Natural Gas Direct Fired Air Heater Installed on Roof for Large Space 6-30 Meter Workshop Warehouse

AirTS was established in 2005 as a technology-driven enterprise that integrates researchand development, manufacturing, sales, and technical services for energy-savingequipment. We are specialized in providing comprehensive solutions for system design, implementation, operation, and maintenance of energy-saving projects.


AirTS product line primarily consists of energy-efficient air conditioning systems specifically designed for high and large space, encompassing heating units, heating and cooling units, gas heating units, gas radiation units, VRF air conditioners, hot air curtain units, industrial HVLS fans, industrial control systems, and other products tailored for large spaces. These solutions effectively resolve diverse requirements such as heating, cooling, ventilation, humidification, dehumidification, dust removal, and
automation control in buildings ranging from 4 to 30 meters in height.

Air Conditioning Unit HVAC System Airts Fresh Air Natural Gas Direct Fired Air Heater Installed on Roof for Large Space 6-30 Meter Workshop Warehouse

Air Conditioning Unit HVAC System Airts Fresh Air Natural Gas Direct Fired Air Heater Installed on Roof for Large Space 6-30 Meter Workshop WarehouseAirTS has collaborated with over 1600 well-known customers, with numerous application cases in the world's top 500 companies.

Air Conditioning Unit HVAC System Airts Fresh Air Natural Gas Direct Fired Air Heater Installed on Roof for Large Space 6-30 Meter Workshop Warehouse

Air Conditioning Unit HVAC System Airts Fresh Air Natural Gas Direct Fired Air Heater Installed on Roof for Large Space 6-30 Meter Workshop WarehouseAir Conditioning Unit HVAC System Airts Fresh Air Natural Gas Direct Fired Air Heater Installed on Roof for Large Space 6-30 Meter Workshop Warehouse

To better ensure the safety of your goods, professional, environmentally friendly, convenient and efficient packaging services will be provided.

Air Conditioning Unit HVAC System Airts Fresh Air Natural Gas Direct Fired Air Heater Installed on Roof for Large Space 6-30 Meter Workshop Warehouse

Air Conditioning Unit HVAC System Airts Fresh Air Natural Gas Direct Fired Air Heater Installed on Roof for Large Space 6-30 Meter Workshop WarehouseAir Conditioning Unit HVAC System Airts Fresh Air Natural Gas Direct Fired Air Heater Installed on Roof for Large Space 6-30 Meter Workshop WarehouseAir Conditioning Unit HVAC System Airts Fresh Air Natural Gas Direct Fired Air Heater Installed on Roof for Large Space 6-30 Meter Workshop Warehouse

1. Who we are
AirTS was established in 2005 as a technology-driven enterprise that integrates research and development, manufacturing, sales, and technical services for energy-saving equipment. We are specialized in providing comprehensive solutions for system design,implementation, operation, and maintenance of energy-saving projects.
2. How to guarantee quality
Always a pre-production sample before mass production; always final Inspection before shipment;
3. What buy from us
Heating units, heating and cooling units, gas heating units, gas radiation units, VRF air conditioners, hot air curtain units, industrial HVLS fans, industrial control systems, and other products tailored for large spaces.
4. Why buy from us not from other suppliers
With 18 years' experience in the market, AirTS has became No.1 market share in China.
5. What services we can provide
Delivery Terms: FOB, CFR, EXW, CIF, Express Delivery;
Payment Currency: USD, CNY;
Payment Type: T/T, L/C, PayPal;
Language: English, Chinese

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now